Mantis Bugtracker

Viewing Issue Simple Details Jump to Notes ] View Advanced ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0000102 [Both Evo and DBA Classic] minor always 2010-02-02 17:43 2010-02-20 11:56
Reporter dkpruett View Status public  
Assigned To JEMM
Priority normal Resolution fixed  
Status resolved  
Summary 0000102: SO-F <F2> on SO # does not bring in SO #
Description When pressing <F2> in the "Print only From Sales Order Number" field, and subsequently selecting a Sales Order in the opened screen, the SO # does not carry back into the "Print only From Sales Order Number" field.
Additional Information
Tags No tags attached.
Banner Date
Error Message
Program Name
Repeatable in Test Company
Attached Files

- Relationships

-  Notes
(0000113)
HecTech (manager)
2010-02-04 12:37

What update are you running? Are you running into this in EVO or DBA?
(0000115)
dkpruett (reporter)
2010-02-04 13:37

Sorry; DBA Classic 2004.1 1/22/10 Update, though this has been occurring for about 1 to 2 years; it also occurs 100% of the time on Vista, 7, Server 2008, and XP, both 32 & 64 bit machines that I'm aware of.
(0000117)
HecTech (manager)
2010-02-05 13:44

Please go into your DBAMFG folder and look for the BKSOF.run file. What is the modified date on the file?
(0000121)
HecTech (manager)
2010-02-19 16:00

Problem is confirmed and only happens in classic not EVO. Bug was tested and confirmed using 1/22/10 update.

- Issue History
Date Modified Username Field Change
2010-02-02 17:43 dkpruett New Issue
2010-02-04 12:37 HecTech Note Added: 0000113
2010-02-04 12:37 HecTech Assigned To => HecTech
2010-02-04 12:37 HecTech Reproducibility always => unable to reproduce
2010-02-04 12:37 HecTech Status new => assigned
2010-02-04 12:37 HecTech Status assigned => acknowledged
2010-02-04 12:38 HecTech Status acknowledged => feedback
2010-02-04 13:37 dkpruett Note Added: 0000115
2010-02-05 13:44 HecTech Note Added: 0000117
2010-02-19 16:00 HecTech Note Added: 0000121
2010-02-19 16:00 HecTech Assigned To HecTech => JEMM
2010-02-19 16:00 HecTech Status feedback => assigned
2010-02-20 11:56 JEMM Reproducibility unable to reproduce => always
2010-02-20 11:56 JEMM Status assigned => resolved
2010-02-20 11:56 JEMM Resolution open => fixed


Mantis 1.1.2[^]
Copyright © 2000 - 2008 Mantis Group
Powered by Mantis Bugtracker